BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Portable Radiometer tritium RKB-05P
DTSTART;VALUE=DATE-TIME:20151007T100000Z
DTEND;VALUE=DATE-TIME:20151007T101500Z
DTSTAMP;VALUE=DATE-TIME:20260423T040443Z
UID:indico-contribution-58-456@cern.ch
DESCRIPTION:Speakers: Egor Voronenko (Yurievich)\nPortable Radiometer trit
 ium RKB-05P created for selective control tritium in the air (in gas and v
 apor phase) and water (in condensate water vapor from the air or in water 
 after distillation) and to measure the activity of other beta-emitting rad
 ionuclides in water sample. The principle of operation is based on measure
 ment of the activity of samples previously taken from the water or air in 
 the measuring cell with special film scintillators or in liquid scintillat
 ors vessels. The device is designed for the control of tritium in enterpri
 ses associated with the use\, receipt or processing of tritium\, as well a
 s for environmental monitoring. The device can be used in the work of the 
 personnel radiation monitoring service\, health care\, environmental prote
 ction and other organizations that solve similar problems monitoring of tr
 itium in samples of air or water.\n\nhttps://indico.particle.mephi.ru/even
 t/2/contributions/456/
LOCATION:Milan Hotel 4* Bellini
URL:https://indico.particle.mephi.ru/event/2/contributions/456/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Measurement of Radon concentration by Xenon gamma-ray spectrometer
  for seismic monitoring of the Earth
DTSTART;VALUE=DATE-TIME:20151007T110000Z
DTEND;VALUE=DATE-TIME:20151007T111500Z
DTSTAMP;VALUE=DATE-TIME:20260423T040443Z
UID:indico-contribution-58-422@cern.ch
DESCRIPTION:Speakers: Alexander Novikov (NRNU MEPhI)\nA method for earthqu
 ake precursors search based on variations of 222Rn concentration determine
 d via intensity measurement of 222Rn daughter nuclei gamma ray emission li
 nes by means of xenon gamma-ray spectrometer is discussed. The equipment d
 escription as well as the first experimental data are presented.\n\nhttps:
 //indico.particle.mephi.ru/event/2/contributions/422/
LOCATION:Milan Hotel 4* Bellini
URL:https://indico.particle.mephi.ru/event/2/contributions/422/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Application peculiarities of magnetic materials for protection fro
 m magnetic fields
DTSTART;VALUE=DATE-TIME:20151007T104500Z
DTEND;VALUE=DATE-TIME:20151007T110000Z
DTSTAMP;VALUE=DATE-TIME:20260423T040443Z
UID:indico-contribution-58-418@cern.ch
DESCRIPTION:Speakers: Phyo Wai (NRNU MEPhI)\nIn different materials for ma
 gnetic shields the maximum permeability is achieved at different values of
  the magnetic field. This determines the choice of material. So for protec
 tion from magnetic fields strength of 10 - 150 A/m is advisable to apply t
 he amorphous ribbon 84KXCP. For stronger fields (more than 400 A/m) multil
 ayer film shields based on Ni20Fe80 should be used. Using these materials 
 allows creating an effective shield working in a wide range of magnetic fi
 eld strengths.\n\nhttps://indico.particle.mephi.ru/event/2/contributions/4
 18/
LOCATION:Milan Hotel 4* Bellini
URL:https://indico.particle.mephi.ru/event/2/contributions/418/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Performances investigation and material selection of PMT magnetic 
 shields for the space experiments with GRIS and PING-M instruments
DTSTART;VALUE=DATE-TIME:20151007T103000Z
DTEND;VALUE=DATE-TIME:20151007T104500Z
DTSTAMP;VALUE=DATE-TIME:20260423T040443Z
UID:indico-contribution-58-401@cern.ch
DESCRIPTION:Speakers: Rodion Faradzhaev (National Research Nuclear Univers
 ity MEPhI)\nScintillation detectors based on Hamamatsu photomultiplier tub
 es (PMTs) R6233-100 and R6231-100 with diameter of photocathode 76 mm and 
 51 mm respectively are used in GRIS experiment\, which is planned to be in
 stalled onboard the ISS\, and in PING-M for Interhelioprobe mission. PMT p
 erformances significantly change under the influence of a magnetic field. 
 Even the relatively weak geomagnetic field\, which typically value is abou
 t 0.5 gauss\, has an appreciable effect. PMT gain variations with photocat
 hode diameter 76 mm may reach 10-20 % depending on spatial orientation. Th
 erefore\, it is necessary to apply magnetic shields for PMT response stabi
 lity enhancement.\n  The performances investigation of magnetic shields ma
 de of steel\, permalloy and amorphous metallic alloy ribbon was carried ou
 t. Influence of the shield position relative to the PMT photocathode was s
 tudied. Based on obtained data the choice of magnetic shield was made.\n\n
 https://indico.particle.mephi.ru/event/2/contributions/401/
LOCATION:Milan Hotel 4* Bellini
URL:https://indico.particle.mephi.ru/event/2/contributions/401/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Effectiveness of protection from low frequency electromagnetic rad
 iation by multilayered film structures
DTSTART;VALUE=DATE-TIME:20151007T101500Z
DTEND;VALUE=DATE-TIME:20151007T103000Z
DTSTAMP;VALUE=DATE-TIME:20260423T040443Z
UID:indico-contribution-58-372@cern.ch
DESCRIPTION:Speakers: Sergei Grabchikov (Scientific-Practical Materials Re
 search Center\, National Academy of Sciences of Belarus)\nThe problem of e
 lectronic and scientific equipment protection becomes more actual nowadays
 . Protection from low-frequency electromagnetic radiation (LF EMR) is the 
 most complicated case of electromagnetic shielding.\nThe results of the sh
 ielding efficiency from LF EMR by multilayer film shields based on permall
 oy / copper systems\, depending on their internal structure\, the paramete
 rs of the EMR\, as well as some examples of practical application are pres
 ented.\n\nhttps://indico.particle.mephi.ru/event/2/contributions/372/
LOCATION:Milan Hotel 4* Bellini
URL:https://indico.particle.mephi.ru/event/2/contributions/372/
END:VEVENT