BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Thermosyphon cryogenic system for RED-100 detector
DTSTART;VALUE=DATE-TIME:20151007T130000Z
DTEND;VALUE=DATE-TIME:20151007T131500Z
DTSTAMP;VALUE=DATE-TIME:20260309T214822Z
UID:indico-contribution-60-434@cern.ch
DESCRIPTION:Speakers: Aleksey Shakirov (MEPhI)\nA cryogenic system based o
 n a two-phase closed tubular thermosyphon with 12 mm diameter copper tube 
 is developed. It was used for thermal stabilization of the liquid xenon em
 ission detector RED-100. The nitrogen refrigerant cooled down with a free-
 boiling liquid nitrogen bath has been used. It was shown that the system s
 upports the RED100 operation at temperature 166 K with accuracy ±1К.\n\n
 https://indico.particle.mephi.ru/event/2/contributions/434/
LOCATION:Milan Hotel 4* Verdi
URL:https://indico.particle.mephi.ru/event/2/contributions/434/
END:VEVENT
BEGIN:VEVENT
SUMMARY:New method of Kr-85 reduction in low-background detectors.
DTSTART;VALUE=DATE-TIME:20151007T123000Z
DTEND;VALUE=DATE-TIME:20151007T124500Z
DTSTAMP;VALUE=DATE-TIME:20260309T214822Z
UID:indico-contribution-60-354@cern.ch
DESCRIPTION:Speakers: Dmitry Akimov (ITEP and MEPhI)\, Grigory Simakov (IT
 EP)\nKrypton-85 is a technogenic beta-radioactive isotope which produces b
 ackground in a low-energy region in dark matter and neutrino detectors: in
  noble gas detectors\, especially in liquid Xenon detectors\, in organic l
 iquid scintillator detectors.\nWe propose a new method of reduction of the
  85Kr isotope in a detector medium based on adding to the detector medium 
 a Krypton sample depleted of the 85Kr isotope and subsequent reduction of 
 the Kr content down to the initial or even lower level with the use of exi
 sting methods of purification. This method works because the residual natu
 ral Kr is diluted in the depleted one and is removed together with it from
  Xe since both of them have the same thermodynamic properties.\nA test cel
 l for measurement of the activity of the depleted Kr has been assembled an
 d the radioactivity of the 25-year-old Krypton has been measured. The meas
 ured activity (56 ± 5 Bq/g) recalculated to the air the air activity due 
 to 85Kr decays in the year 1990 (1.20 ± 0.10 Bq/m3) is close to the data 
 on the air activity at that time.\n\nhttps://indico.particle.mephi.ru/even
 t/2/contributions/354/
LOCATION:Milan Hotel 4* Verdi
URL:https://indico.particle.mephi.ru/event/2/contributions/354/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Study of electron emission in a two-phase xenon detector
DTSTART;VALUE=DATE-TIME:20151007T124500Z
DTEND;VALUE=DATE-TIME:20151007T130000Z
DTSTAMP;VALUE=DATE-TIME:20260309T214822Z
UID:indico-contribution-60-352@cern.ch
DESCRIPTION:Speakers: Alexey Konovalov (MEPhI/ITEP)\nWe describe basic pri
 nciples of electron emission in two-phase xenon and discuss possible ways 
 of spontaneous electron emission. We present a brief summary of experiment
 al results connected to single electron emission including the recent one 
 obtained by the authors. The results of study seem to confirm the hypothes
 is\, that single electron signals originate from the cloud of ionization e
 lectrons localised under the liquid-gas interface.\n\nhttps://indico.parti
 cle.mephi.ru/event/2/contributions/352/
LOCATION:Milan Hotel 4* Verdi
URL:https://indico.particle.mephi.ru/event/2/contributions/352/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Study of the low-background Hamamatsu R11410-20 cryogenic PMTs for
  the RED100 detector
DTSTART;VALUE=DATE-TIME:20151007T131500Z
DTEND;VALUE=DATE-TIME:20151007T133000Z
DTSTAMP;VALUE=DATE-TIME:20260309T214822Z
UID:indico-contribution-60-306@cern.ch
DESCRIPTION:Speakers: Yury Melikyan (NRNU MEPhI)\nThe two-phase cryogenic 
 xenon emission detector RED100 is planned to be equipped by 38 Hamamatsu R
 11410-20 photomultiplier tubes\, which are claimed to be operable at cryog
 enic temperatures and made of extremely low background materials.\nA thoro
 ugh characterization procedure has been carried out for each PMT unit to b
 e installed to the detector. The main results obtained are presented here\
 , including the single photoelectron spectra parameters\, a set of gain-re
 presenting curves for a wide range of the bias voltage values\, typical am
 plitude integral spectrum of the PMT’s dark count rate and the distribut
 ion of 34 PMT samples through their dark count rate for equal gain values.
  Peculiar characteristics of several PMT units are further discussed and e
 xplained.\n\nhttps://indico.particle.mephi.ru/event/2/contributions/306/
LOCATION:Milan Hotel 4* Verdi
URL:https://indico.particle.mephi.ru/event/2/contributions/306/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Data acquisition system based on fast waveform digitizer for large
  neutrino detectors
DTSTART;VALUE=DATE-TIME:20151007T120000Z
DTEND;VALUE=DATE-TIME:20151007T121500Z
DTSTAMP;VALUE=DATE-TIME:20260309T214822Z
UID:indico-contribution-60-303@cern.ch
DESCRIPTION:Speakers: Georgy Lukyanchenko (NRC Kurchatov Institute)\nFor l
 arge volume neutrino and antineutrino detectors it is crucial to have an e
 fficient data acquisition system capable of digitizing data from thousands
  of detection channels. Here we present a flexible DAQ system architecture
  consisting of large number of fast waveform digitizers and configurable F
 PGA-based trigger logic. Current implementation of the system is functioni
 ng in the Borexino detector providing zero dead time spectroscopy data in 
 energy range from 1 up to 100 MeV. Acquisition complex in combination with
  our custom analysis software is successfully being used for registration 
 of geoneutrinos\, as well as search for neutrino signal from GRBs\, solar 
 netrino spectroscopy and other aplications.\n\nhttps://indico.particle.mep
 hi.ru/event/2/contributions/303/
LOCATION:Milan Hotel 4* Verdi
URL:https://indico.particle.mephi.ru/event/2/contributions/303/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Digital trigger system for the RED-100 detector based on the unit 
 in VME standard
DTSTART;VALUE=DATE-TIME:20151007T121500Z
DTEND;VALUE=DATE-TIME:20151007T123000Z
DTSTAMP;VALUE=DATE-TIME:20260309T214822Z
UID:indico-contribution-60-289@cern.ch
DESCRIPTION:Speakers: Pavel Naumov (MEPhI)\nThe system for forming a trigg
 er for the RED-100 liquid xenon detector has been developed. The trigger c
 an be generated for all types of events required to calibrate the detector
  and data acquisition\, including events with one ionization electron. The
  system has an event detection mechanism where each event is assigned with
  the timestamp and event type. The trigger system is required in the syste
 ms searching for rare events to keep only the necessary information from t
 he ADC array. The characteristics and implementation of the trigger system
  that provides high efficiency operation even at low-energy events have be
 en described.\n\nhttps://indico.particle.mephi.ru/event/2/contributions/28
 9/
LOCATION:Milan Hotel 4* Verdi
URL:https://indico.particle.mephi.ru/event/2/contributions/289/
END:VEVENT