BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Recovery Time Measurements of the Hamamatsu Linear Assembly SiPM
DTSTART;VALUE=DATE-TIME:20181022T124000Z
DTEND;VALUE=DATE-TIME:20181022T151000Z
DTSTAMP;VALUE=DATE-TIME:20260423T032412Z
UID:indico-contribution-1233@cern.ch
DESCRIPTION:Speakers: Fred Kayumov (LPI\, MEPhI)\nAbstract. The pixel reco
 very time of the Hamamatsu SiPM linear assembly was measured. The assembly
  contains eight SiPMs of 2.8 mm active area diameter\; pixel size is 15 x 
 15 mkm2. The assembly is used in calorimeters of the CMS experiment.\nThe 
 measurements were made for two groups of pixels: 49 and 17 pixels. Recover
 ing time was found as 7 ns and 6 ns respectively.\nThe amplifier of 40 db 
 and digital oscilloscope TDS3052 Tektronix were used when measurements.\n\
 nhttps://indico.particle.mephi.ru/event/22/contributions/1233/
LOCATION:Hotel Intourist Kolomenskoye 4* Petrovskiy hall
URL:https://indico.particle.mephi.ru/event/22/contributions/1233/
END:VEVENT
END:VCALENDAR