SUMMARY:Preparation of CMS Hadron Endcap calorimeter front-end upgrade
DTSTART;VALUE=DATE-TIME:20161014T140000Z
DTEND;VALUE=DATE-TIME:20161014T141500Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-795@cern.ch
DESCRIPTION:Speakers: Oksana Bychkova (NRNU MEPhI)\nThe hadron endcap (HE)
  calorimeter is one of the major sections of CMS hadron calorimeter\, whic
 h is used for measurement of the hadrons energy. Upgrade of the front-end 
 electronics components in the existing HE calorimeter is planned for a num
 ber of reasons. New charge integrator encoder (QIE11) shunt tests and DC/D
 C converter calibration were carried out in preparation for HE calorimeter
  upgrade phase 1. Analysis and measurement results for the new generation 
 front-end electronics components are presented.\n\nhttps://indico.particle
 .mephi.ru/event/4/contributions/795/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/795/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Geant4 simulation of optical photon transport in scintillator tile
  with direct readout by silicon photomultiplier
DTSTART;VALUE=DATE-TIME:20161014T133000Z
DTEND;VALUE=DATE-TIME:20161014T134500Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-733@cern.ch
DESCRIPTION:Speakers: Sergey Korpachev (MEPhI)\nActive elements in the bas
 eline design of the highly granular calorimeters proposed for future colli
 der experiments are scintillator tiles with silicon photomultiplier readou
 t. The direct coupling of SiPm to scintillator is considered to be the mai
 n option for such detectors. In this study\, the response of scintillator-
 SiPm system to minimum ionizing particle was simulated using the optical p
 hoton transport functionality available in the Geant4 package.  The model 
 was tuned using a comparison with experimental results. The uniformity of 
 response for flat and dimpled tile surfaces was estimated. Such simulation
  studies are important for optimization of detector elements not only for 
 high-energy physics\, but also for medical applications.\n\nhttps://indico
 .particle.mephi.ru/event/4/contributions/733/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/733/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Timing scintillation detector with SiPM incorporated throughout a 
 scintillator’s body
DTSTART;VALUE=DATE-TIME:20161014T131500Z
DTEND;VALUE=DATE-TIME:20161014T133000Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-687@cern.ch
DESCRIPTION:Speakers: Nikita Vozniuk (MEPhI)\nA timing scintillation detec
 tor based on a plastic scintillator tile sized 35x5x1 cm3 and SiPM optical
  readout has been developed and characterized. For the best uniformity of 
 the detector’s response to particle hits across its area\, a set of SiPM
  optical sensors has been incorporated into the scintillator throughout it
 s volume. Time resolution better than 250 ps (sigma) has been achieved for
  each point of the device. Uniformity of the detector’s response is conf
 irmed by amplitude measurements along the tile as well as measurements of 
 the efficiency of scintillation detection\, which\, on average\, is not wo
 rse than 99%.\n\nhttps://indico.particle.mephi.ru/event/4/contributions/68
 7/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/687/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Application of SiPM for Modern Nuclear Physics Practical Workshop
DTSTART;VALUE=DATE-TIME:20161014T143000Z
DTEND;VALUE=DATE-TIME:20161014T144500Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-679@cern.ch
DESCRIPTION:Speakers: Olga Gavrilenko (Igorevna)\nSilicon Photo-Multiplier
 s (SiPM) are state of the art light detectors with very high single photon
  sensitivity and photon number resolving capability\, representing a break
 through in several fundamental and applied Science domains. So\, introduct
 ion of SiPM in to the education is important process increasing the number
  of specialists involved in the SiPM development and application. As a res
 ult of collaborative efforts between industry and academic institutions mo
 dular set of instruments based on SiPM light sensors has been developed by
  CAEN s.p.a. It is developed for educational purposes mainly and allows pe
 rforming a series of experiments including photon detection\, gamma spectr
 ometry\, cosmic ray observation and beta and gamma ray absorption. In addi
 tion\, an educational experiments based on a SiPM set-up guides students t
 owards a comprehensive knowledge of SiPM technology while experiencing the
  quantum nature of light and exploring the statistical properties of the l
 ight pulses emitted by a LED. The toolbox is actually an open platform in 
 continuous evolution thanks to the contribution of the research community 
 and cooperation with high schools.\n\nThe work was supported by a program 
 of the ministry of education and science of The Russian Federation for hig
 her education establishments\, project №14.578.21.0192 (RFMEFI57816X0192
 ).\n\nhttps://indico.particle.mephi.ru/event/4/contributions/679/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/679/
END:VEVENT
BEGIN:VEVENT
SUMMARY:A method for lateral localization of a compact gamma source in rad
 ionuclide diagnostics
DTSTART;VALUE=DATE-TIME:20161014T130000Z
DTEND;VALUE=DATE-TIME:20161014T131500Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-621@cern.ch
DESCRIPTION:Speakers: Irina Pashkovich (MEPhI)\nTo determine the depth of 
 the area of radiopharmaceutical accumulation a method based on simultaneou
 s registration of two gamma ray lines of different energies and quantitati
 ve comparison of the intensity of these lines on the surface of the patien
 t's body is developed. The most widely used medical radioisotope technetiu
 m-99m has two gamma-lines - 140 keV and 18 keV\, which allows one to apply
  the proposed method to search for the sentinel lymph nodes and non-palpab
 le malignant tumors in the soft tissues. The result is achieved by the qua
 ntitative analysis of the areas of absorption peaks of technecium-99m. A d
 edicated scintillation detector optimized for low energy gamma rays regist
 ration was designed. This miniature detector consists of a LaBr3:Ce scinti
 llation crystal and a silicon photomultiplier packed together is a sealed 
 aluminum housing with a wall thickness of 0.2 mm. The proposed detector wa
 s used in a set of experimental studies which showed that the lateral coor
 dinate of the Tc-99m source can be determined with an accuracy of ± 4 mm 
 at the depth up to 30 mm a tissue-equivalent phantom.\n\nhttps://indico.pa
 rticle.mephi.ru/event/4/contributions/621/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/621/
END:VEVENT
BEGIN:VEVENT
SUMMARY:The silicon photomultipliers in the detector subsystems of the Glu
 eX experiment
DTSTART;VALUE=DATE-TIME:20161014T141500Z
DTEND;VALUE=DATE-TIME:20161014T143000Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-553@cern.ch
DESCRIPTION:Speakers: Vladimir Berdnikov (NRNU MEPhI)\nThe subsystem detec
 tors of the GlueX experiment uses the silicon photomultiplier (SiPM) photo
 detectors. The detectors operate  in condition of 2MHz load level  and up 
 to 104 pixels «fired» with ~0.3ns time resolution. The list of such dete
 cors : the scintillating mycroscope to determine the energy of a beam phot
 on by detecting the bremsstrahlung electron after radiation\; the magnet s
 pectrometer of the electron positron pair to measure the spectra of linear
 ly polarized photons\; the start counter which surround the liquid hydroge
 n target and whose main goal is to identify the beam bucket associated wit
 h the interaction\; the electromagnetic barrel calorimeter to measure the 
 energy and the direction of secondary photons comes from the target. Aroun
 d five thousand SiPM`s in total uses in the detectors of experiment. We pr
 esent the results of the time resolution measurements and the relaxation t
 ime measurements for two SiPM types in the experimental conditions. The fi
 rst is the SiPM with matrix specially developed for the experiment and the
  second is the SiPM with different size of pixels.\n\nhttps://indico.parti
 cle.mephi.ru/event/4/contributions/553/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/553/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Study of the neutron irradiation effect on SiPM based 10-channel p
 rototype of scintillation detector module produced at JINR.
DTSTART;VALUE=DATE-TIME:20161014T134500Z
DTEND;VALUE=DATE-TIME:20161014T140000Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-549@cern.ch
DESCRIPTION:Speakers: Sergey Reznikov (JINR)\nThe detectors based on solid
 -state photomultipliers (SiPM) are proposed for\nforthcoming experiments p
 lanned with relativistic heavy ions at FAIR\n(CBM) and at NICA (MPD).\nThe
  main radiation damage of the detectors located along the beam axis is\nca
 used by neutrons. The forward calorimeter PSD@CBM is equipped with\n  SiPM
 . The fluence up to 10e13 n/cm2 during first months\n  of the CBM experime
 nt at position of SiPM is expected.\n  Therefore we have investigated SiPM
  based 10-channel prototype of\n  scintillation detector module produced a
 t JINR by irradiating it with\n  quasi-monoenergetic neutrons of peak ener
 gy 32 MeV  and fluence ~3*10e8\n  n/cm2. Secondary neutron beam was  produ
 ced in the 7Li(p\,n)7Be neutron\n  generator at the NPI cyclotron (Rez\, C
 zech Republic).\n\n  It is shown that the module electronics remains opera
 tional\, but the\n  noise of SiPM increased. We applied new method to moni
 tor changes in the\n  breakdown voltage without measurement of SiPMs I-V c
 haracteristics. The\n  method is based on measurement of the dependence of
  Vpp and Vrms voltage\n  on the bias voltage. The proposed method can be a
 pplied for monitoring of\n  changes in the breakdown voltage during the de
 tector  operation and does\n  not require the usage of the additional equi
 pment.\n\nhttps://indico.particle.mephi.ru/event/4/contributions/549/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/549/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Advanced Processing of SiPM Timing Resolution
DTSTART;VALUE=DATE-TIME:20161014T124500Z
DTEND;VALUE=DATE-TIME:20161014T130000Z
DTSTAMP;VALUE=DATE-TIME:20260814T154133Z
UID:indico-contribution-96-530@cern.ch
DESCRIPTION:Speakers: Dmitry Philippov (NRNU MEPHI)\nStandards analog tech
 nique in experimental physics doesn't allow to achieve very high timing re
 solutions of the detectors based on SiPMs and fast scintillators. One of t
 he reasonable method to obtain that more precisely is usage the digital pr
 ocessing algorithms.\n\nWe measured single photon timing resolution (SPTR)
  of a series of timing optimized KETEK SiPM samples of 3x3 mm2 and coincid
 ence timing resolution (CTR) of long and short LYSO crystals with same pho
 todetectors. The results of usage the offline digital processing algorithm
  on this data will be presented.\n\nhttps://indico.particle.mephi.ru/event
 /4/contributions/530/
LOCATION:Milan Hotel Verdi
URL:https://indico.particle.mephi.ru/event/4/contributions/530/
END:VEVENT