The investigation of timing large area scintillation detectors with SiPM light sensors properties.

13 Oct 2016, 17:00
15m
Verdi (Milan Hotel)

Verdi

Milan Hotel

Shipilovskaya Street, 28A, Moscow, Russia, 115563
Plenary/section talk Cosmic rays Cosmic rays - parallel VI

Speaker

Mr. Peter Naumov (NRNU MEPhI)

Description

The timing large area plastic scintillation detectors with silicon photomultipliers as photosensors properties were investigated using a cosmic radiation at the ground level. Different techniques of the amplitude spectra and efficiency measurements were implemented. The measurements results are presented also.