Mr.
Ilyas Sagdiev
(NRNU MEPHI)
14/10/2016, 09:30
A low power area efficient 5 bit current steering DAC is presented. The proposed DAC is integrated to prototype the readout channel for muon chamber in CBM experiment. DAC was implemented with an area of 0.019 mm2 in the CMOS process using UMS MMRF 180 nm technology. This DAC has ultralow power consumption - 25μW. The measured differential nonlinearity (DNL) is better than 0.25 LSB, integral...
Ms.
Ksenia Kirillovykh
(student)
14/10/2016, 09:30
Kirillovykh E.V., Nikitaev V.G.,1, Ulin S.E.1, Polyakov E.V.1,
Trubilin V.N., Orlova O.M..
1National Research Nuclear University «MEPhI» (NRNU MEPhI)
Russia, 115409, Moscow, Kashirskoe shosse, 31
2Ophthalmology Centre FMBA of Russia
Russia 123098, Moscow, Gamalei st., 15.
Automation aid system for an ophthalmologist is being proposed. The system is to enable an ophthalmologist...
Mr.
Dmitry Normanov
(NRNU Mephi)
14/10/2016, 09:30
A low-power digital peak detector, intended for use in a 32-channel IC, reading out and processing the signals of the FAIR accelerator detectors of the CBM experiment, is considered. In compare with its analogues the peak detector (PD) has been added by an option of correcting input disturbances, which may be digitized by on ADC. The block has been designed for operation with an 8-bit ADC,...
Mr.
Pavel Ivanov
(NRNU MEPhI)
14/10/2016, 09:30
An application specific design flow for multichannel analog-digital ICs for front end electronics is presented. The design flow allows to reduce the terms of designing the IC, raise the efficiencies of CAD operation and reach substantially better parameters of the IC in performance, occupied area and power consumption. This flow was successfully applied to the design of the readout ASIC...
Mr.
Oleg Shumkin
(National Research Nuclear University MEPhI (Moscow Engineering Physics Institute))
14/10/2016, 09:30
The structure of the interface of data exchange with the GBTX chip for the CBM experiment is considered. The interface generate data package, consisting of the digital codes of signal amplitude, of signal superposition in peak detector, of signal arrival time and channel number, wherein the event has occurred, generated by the readout blocks of IC. The created data package is coded according...
Mr.
Evgeniy Polyakov
(postgreduet)
14/10/2016, 09:30
Nikitaev V.G., Polyakov E.V.
National Research Nuclear University «MEPhI» (NRNU MEPhI)
Russia, 115409, Moscow, Kashirskoe shosse, 31
The paper considers random component error study while measuring characteristics of cell nuclei structure with application of structural unit technique. Poor accuracy may result in an incorrect diagnosis. Error estimation has been carried out in the...
Ms.
Olga Sukhova
(Student of NRNU MEPHI)
14/10/2016, 09:30
1National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Russian Federation, 115409, Moscow, Kashirskoe shosse, 31
2N.N. Blokhin Russian Cancer Research Center, Russian Federation,
115478, Moscow, Kashirskoe shosse, 23
3A.I. Evdokimov Moscow State University of Medicine and Dentistry, Russian Federation, 127473, Moscow, Delegatskaya st., 20/1.
The method of...
Mr.
Evgeniy Polyakov
(postgreduet)
14/10/2016, 09:30
Nikitaev V.G., Polyakov E.V.
National Research Nuclear University «MEPhI» (NRNU MEPhI)
Russia, 115409, Moscow, Kashirskoe shosse, 31
The effect of artifacts on the result of blast and lymphocytes separation in the task of diagnosing of acute leukemia types is under consideration. Within the framework of the investigation, a group of artifacts was formed and a technique for study has been...
Mr.
Zakharenko Yury
(undergraduate)
14/10/2016, 09:30
One of the main stages of blood and bone marrow cells recognition at the acute leukemia diagnosing is the leukocyte segmentation. The quality of cell separation methods in computer microscopy can be constrained by different exposure conditions which can in turn cause worse segmentation quality. Leukocyte segmentation efficiency based on the histogram method is considered in the paper.
Ms.
Oksana Bychkova
(NRNU MEPhI)
14/10/2016, 09:30
A method for 222Rn concentration monitoring by means of intensity measurement of its daughter nuclei (214Pb and 214Bi) gamma-ray emission using xenon gamma-ray spectrometer is presented. Testing and calibration results for a gamma-spectrometric complex based on xenon gamma-ray detector are described.
Mr.
Pavel Parygin
(NRNU MEPhI)
14/10/2016, 09:30
Silicon photomultipliers (SiPM) are very promising semiconductor single photon sensitive devices with high gain. One of the challenge of use these detectors in radiation environment such as high energy physics experiments is a radiation hardness.
Experimental samples were produced and then irradiated with different doses of X-rays with energy E≈12 keV. Simulation of these SiPMs was...
Mr.
Alexander Novikov
(NRNU MEPhI, The University of Kansas)
14/10/2016, 09:30
Hi-Cal (High-Altitude Calibration) is a balloon experiment that will be launched in Antarctica after ANITA-IV (Antarctic Impulsive Transient Antenna) and will generate a wide beam pulse in the frequency range expected from radiation induced from a cosmic ray shower. In this work a device based on an array of silicon photomultipliers (SiPMs) for determination of the azimuthal position of Hi-Cal...
Mr.
Malankin Evgeny
(NRNU MEPHI)
14/10/2016, 09:30
The paper describes methodology of substrate noise isolation for ASICs implemented in the CMOS processes. Up-to-date CMOS technologies allow embedding the digital processing blocks into the same die as the readout analog part. This significantly improves the functionality and complexity of the readout ASICs. In fact performance of the precision analog circuits (e.g. charge sensitive amplifier,...
Mrs.
Polina Korenevskaya
(undergraduate)
14/10/2016, 09:30
Polyakov E.V.1, Sukhova O.G.1, Korenevskaya P.Yu.1, Ovcharova V.S.1,
Kudryavtseva I.O.1, Vlasova S. V.1, Selchuk, V.Y.1, 2, 3
1National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Russian Federation, 115409, Moscow, Kashirskoe shosse, 31
2N.N. Blokhin Russian Cancer Research Center, Russian Federation, Russian Federation, 115478, Moscow, Kashirskoe shosse,...
Ms.
Anastasia Aksenova
(National Nuclear Research University "MEPHI")
,
Prof.
Valery Samosadnyi
(NRNU MEPHI)
14/10/2016, 09:30
The trend of using of the radiaton with shorter wave length in leading high technological processes demands the detected search of materials for the solid-state electronics equipment and optical systems of an ultra violet and vacuum ultra violet spectral range. Diamond photon detectors of ultra violet radiation have the advantage of their opponents due to their unique properties, such as high...